Review




Structured Review

Mini Mitter Company actiware-sleep® v. 5.59 analysis software
Actiware Sleep® V. 5.59 Analysis Software, supplied by Mini Mitter Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+sleep+software/pm33987669-54-16-21
Average 90 stars, based on 1 article reviews
actiware-sleep® v. 5.59 analysis software - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

other:

Article Title: Percent Emphysema and Daily Motor Activity Levels in the General Population
Article Snippet: Epoch length was set to 30 seconds, and activity count was then processed using the Actiware-Sleep version 5.59 analysis software (Mini Mitter Co., Inc.), a validated weighting algorithm, 41 and scored at a central reading center.

Article Title: Sleep Duration and Quality in Relation to Autonomic Nervous System Measures: The Multi-Ethnic Study of Atherosclerosis (MESA)
Article Snippet: Actigraphic data during 30-sec epochs were scored as sleep or wake by Actiware-Sleep v.5.59 analysis software (Mini Mitter Co., Inc., Bend, OR) after manually editing the sleep period using sleep diary data and event and light markers.

Article Title: Gender differences in the association of insomnia symptoms and coronary artery calcification in the multi-ethnic study of atherosclerosis.
Article Snippet: Ac ce pte d M an us cri pt Study Objectives: To quantify the gender-specific associations between insomnia symptoms and subclinical atherosclerosis, measured by coronary artery calcium (CAC) scores, which has strong predictive value for incident cardiovascular disease.. Methods: We analyzed data from 1,429 participants in the Multi-Ethnic Study of Atherosclerosis (MESA).. Participants completed standardized questionnaires and underwent polysomnography (PSG) and 7-day actigraphy.

Article Title: Association of Sleep Duration and Quality With Alterations in the Hypothalamic-Pituitary Adrenocortical Axis: The Multi-Ethnic Study of Atherosclerosis (MESA)
Article Snippet: Actigraphic data during 30-second epochs were scored as sleep or wake by Actiware-Sleep version 5.59 analysis software (Mini Mitter Co, Inc).

Article Title: Sleep Disturbances and Depression in the Multi-Ethnic Study of Atherosclerosis
Article Snippet: 35 Actigraphic data were scored during 30-sec epochs as sleep or wake by Actiware-Sleep version 5.59 analysis software (Mini Mitter Co, Inc, Bend, OR, USA.).

Article Title: Cross-sectional and Prospective Associations of Actigraphy-Assessed Sleep Regularity With Metabolic Abnormalities: The Multi-Ethnic Study of Atherosclerosis
Article Snippet: Using Actiware-Sleep version 5.59 analysis software (Mini Mitter Co., Inc., Bend, OR), every 30-s epoch of actigraphic data was scored as sleep or wake, with sleep onset annotated based on changes in activity count coupled with information from the marker input by participants, environmental light, and sleep timing recorded on sleep diary.

Article Title: Sleep Irregularity and Risk of Cardiovascular Events: The Multi-Ethnic Study of Atherosclerosis
Article Snippet: The data were processed by a certified technician at the Sleep Reading Center of Brigham and Women’s Hospital using Actiware-Sleep version 5.59 analysis software (Mini Mitter Co., Inc. Bend, OR).

Software:

Article Title: Mediterranean diet pattern and sleep duration and insomnia symptoms in the Multi-Ethnic Study of Atherosclerosis
Article Snippet: The MESA Sleep protocol included 7 day actigraphy (Actiwatch Spectrum, Philips Respironics, Murrysville, PA) together with a sleep diary. .. The actigraphy data during 30 s epochs were scored as sleep or wake by Actiware-Sleep v. 5.59 analysis software (Mini Mitter Co., Inc., Bend, OR) and a validated algorithm [ 29 ] in which activity counts recorded during the measured epoch were modified by the level of activity in the surrounding 2 min time period (i.e. ±2 min) to yield a final activity count for each epoch. ..

Activity Assay:

Article Title: Mediterranean diet pattern and sleep duration and insomnia symptoms in the Multi-Ethnic Study of Atherosclerosis
Article Snippet: The MESA Sleep protocol included 7 day actigraphy (Actiwatch Spectrum, Philips Respironics, Murrysville, PA) together with a sleep diary. .. The actigraphy data during 30 s epochs were scored as sleep or wake by Actiware-Sleep v. 5.59 analysis software (Mini Mitter Co., Inc., Bend, OR) and a validated algorithm [ 29 ] in which activity counts recorded during the measured epoch were modified by the level of activity in the surrounding 2 min time period (i.e. ±2 min) to yield a final activity count for each epoch. ..

Modification:

Article Title: Mediterranean diet pattern and sleep duration and insomnia symptoms in the Multi-Ethnic Study of Atherosclerosis
Article Snippet: The MESA Sleep protocol included 7 day actigraphy (Actiwatch Spectrum, Philips Respironics, Murrysville, PA) together with a sleep diary. .. The actigraphy data during 30 s epochs were scored as sleep or wake by Actiware-Sleep v. 5.59 analysis software (Mini Mitter Co., Inc., Bend, OR) and a validated algorithm [ 29 ] in which activity counts recorded during the measured epoch were modified by the level of activity in the surrounding 2 min time period (i.e. ±2 min) to yield a final activity count for each epoch. ..



Similar Products

90
Respironics actg analysis software actiware
Actg Analysis Software Actiware, supplied by Respironics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+analysis+software++version+6+0+2/pm35361553-50-27-34
Average 90 stars, based on 1 article reviews
actg analysis software actiware - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Respironics actiware analysis software
Actiware Analysis Software, supplied by Respironics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+analysis+software++version+6+0+2/pm32988292-74-6-6
Average 90 stars, based on 1 article reviews
actiware analysis software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Respironics actiware analysis software (version 6.0.2
Actiware Analysis Software (Version 6.0.2, supplied by Respironics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+analysis+software++version+6+0+2/pm32988292-74-7-6
Average 90 stars, based on 1 article reviews
actiware analysis software (version 6.0.2 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Respironics actiware 5.52 analysis software
Actiware 5.52 Analysis Software, supplied by Respironics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+software/pm34245182-62-18-23
Average 90 stars, based on 1 article reviews
actiware 5.52 analysis software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Mini Mitter Company actiware-sleep® v. 5.59 analysis software
Actiware Sleep® V. 5.59 Analysis Software, supplied by Mini Mitter Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+sleep+software/pm33987669-54-16-21
Average 90 stars, based on 1 article reviews
actiware-sleep® v. 5.59 analysis software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Philips Healthcare actigraphy analysis software philips actiware v.6.0.8
Actigraphy Analysis Software Philips Actiware V.6.0.8, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actigraphy+software+philips+actiware+6/pm33124122-56-5-8
Average 90 stars, based on 1 article reviews
actigraphy analysis software philips actiware v.6.0.8 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Respironics actiware analysis software version 6.0.2
Actiware Analysis Software Version 6.0.2, supplied by Respironics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+analysis+software++version+6+0+2/pm32029332-120-6-5
Average 90 stars, based on 1 article reviews
actiware analysis software version 6.0.2 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Mini Mitter Company actiware-sleep version 5.59 analysis software
Actiware Sleep Version 5.59 Analysis Software, supplied by Mini Mitter Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+sleep+software/pmc07237955-153-19-24
Average 90 stars, based on 1 article reviews
actiware-sleep version 5.59 analysis software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Respironics actigraphy analysis software actiware version 6.0.9
Reported sleep parameters determined by polysomnography and <t> actigraphy </t>
Actigraphy Analysis Software Actiware Version 6.0.9, supplied by Respironics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actigraphy+analysis+software+actiware+version+6+0+9/pmc07844945-129-13-20
Average 90 stars, based on 1 article reviews
actigraphy analysis software actiware version 6.0.9 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Mini Mitter Company actigraphy data analysis software actiware-sleep v. 5.59
Reported sleep parameters determined by polysomnography and <t> actigraphy </t>
Actigraphy Data Analysis Software Actiware Sleep V. 5.59, supplied by Mini Mitter Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/actiware+analysis+software/actiware+sleep+software/pmc06231522-152-14-19
Average 90 stars, based on 1 article reviews
actigraphy data analysis software actiware-sleep v. 5.59 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Reported sleep parameters determined by polysomnography and  actigraphy

Journal: Critical Care

Article Title: The feasibility and reliability of actigraphy to monitor sleep in intensive care patients: an observational study

doi: 10.1186/s13054-020-03447-8

Figure Lengend Snippet: Reported sleep parameters determined by polysomnography and actigraphy

Article Snippet: ACTG data was analyzed as sleep or wake at 30-s epochs via the actigraphy analysis software (Actiware version 6.0.9; Phillips Respironics), using the predetermined activity count for each epoch within the software algorithm.

Techniques:

Correlations of Polysomnography and  Actigraphy  sleep parameters

Journal: Critical Care

Article Title: The feasibility and reliability of actigraphy to monitor sleep in intensive care patients: an observational study

doi: 10.1186/s13054-020-03447-8

Figure Lengend Snippet: Correlations of Polysomnography and Actigraphy sleep parameters

Article Snippet: ACTG data was analyzed as sleep or wake at 30-s epochs via the actigraphy analysis software (Actiware version 6.0.9; Phillips Respironics), using the predetermined activity count for each epoch within the software algorithm.

Techniques:

Bland–Altman plots: Horizontal line drawn at the mean difference and at the mean difference plus and minus 1.96 times the standard deviation of the differences, with the y-axis reporting mean duration determine by polysomnography. a Polysomnography versus Actigraphy assessment of total sleep time. b Polysomnography versus Actigraphy assessment of wakeful states for the study cohort. Graphs c and d depict Polysomnography versus Actigraphy assessment of total sleep time amongst mechanically ventilated patients ( c ) and Polysomnography versus Actigraphy assessment of wakeful states for patients receiving mechanical ventilation ( d ). Non-ventilated patient total sleep time (PSG vs ACTG), and wake time (PSG vs ACTG) is represented in graph e and f

Journal: Critical Care

Article Title: The feasibility and reliability of actigraphy to monitor sleep in intensive care patients: an observational study

doi: 10.1186/s13054-020-03447-8

Figure Lengend Snippet: Bland–Altman plots: Horizontal line drawn at the mean difference and at the mean difference plus and minus 1.96 times the standard deviation of the differences, with the y-axis reporting mean duration determine by polysomnography. a Polysomnography versus Actigraphy assessment of total sleep time. b Polysomnography versus Actigraphy assessment of wakeful states for the study cohort. Graphs c and d depict Polysomnography versus Actigraphy assessment of total sleep time amongst mechanically ventilated patients ( c ) and Polysomnography versus Actigraphy assessment of wakeful states for patients receiving mechanical ventilation ( d ). Non-ventilated patient total sleep time (PSG vs ACTG), and wake time (PSG vs ACTG) is represented in graph e and f

Article Snippet: ACTG data was analyzed as sleep or wake at 30-s epochs via the actigraphy analysis software (Actiware version 6.0.9; Phillips Respironics), using the predetermined activity count for each epoch within the software algorithm.

Techniques: Standard Deviation